- Title
- Nasal high-flow therapy for newborn infants in special care nurseries
- Creator
- Manley, Brett J.; Arnolda, Gaston R. B.; Wright, Ian M. R.; Owen, Louise S.; Foster, Jann P.; Huang, Li; Roberts, Calum T.; Clark, Tracey L.; Fan, Wei-Qi; Fang, Alice Y. W.; Marshall, Isaac R.; Pszczola, Rosalynn J.; Davis, Peter G.; Buckmaster, Adam G.
- Relation
- NHMRC.1098790 http://purl.org/au-research/grants/nhmrc/1098790
- Relation
- New England Journal of Medicine Vol. 380, p. 2031-2040
- Publisher Link
- http://dx.doi.org/10.1056/NEJMoa1812077
- Publisher
- Massachusetts Medical Society
- Resource Type
- journal article
- Date
- 2019
- Description
- Background: Nasal high-flow therapy is an alternative to nasal continuous positive airway pressure (CPAP) as a means of respiratory support for newborn infants. The efficacy of high-flow therapy in nontertiary special care nurseries is unknown. Methods: We performed a multicenter, randomized, noninferiority trial involving newborn infants (<24 hours of age; gestational age, ≥31 weeks) in special care nurseries in Australia. Newborn infants with respiratory distress and a birth weight of at least 1200 g were assigned to treatment with either high-flow therapy or CPAP. The primary outcome was treatment failure within 72 hours after randomization. Infants in whom high-flow therapy failed could receive CPAP. Noninferiority was determined by calculating the absolute difference in the risk of the primary outcome, with a noninferiority margin of 10 percentage points. Results: A total of 754 infants (mean gestational age, 36.9 weeks, and mean birth weight, 2909 g) were included in the primary intention-to-treat analysis. Treatment failure occurred in 78 of 381 infants (20.5%) in the high-flow group and in 38 of 373 infants (10.2%) in the CPAP group (risk difference, 10.3 percentage points; 95% confidence interval [CI], 5.2 to 15.4). In a secondary per-protocol analysis, treatment failure occurred in 49 of 339 infants (14.5%) in the high-flow group and in 27 of 338 infants (8.0%) in the CPAP group (risk difference, 6.5 percentage points; 95% CI, 1.7 to 11.2). The incidences of mechanical ventilation, transfer to a tertiary neonatal intensive care unit, and adverse events did not differ significantly between the groups. Conclusions: Nasal high-flow therapy was not shown to be noninferior to CPAP and resulted in a significantly higher incidence of treatment failure than CPAP when used in nontertiary special care nurseries as early respiratory support for newborn infants with respiratory distress. (Funded by the Australian National Health and Medical Research Council and Monash University; HUNTER Australian and New Zealand Clinical Trials Registry number, ACTRN12614001203640.)
- Subject
- nasal high-flow therapy; newborn infant; special care nurseries; respiratory support
- Identifier
- http://hdl.handle.net/1959.13/1428015
- Identifier
- uon:38591
- Identifier
- ISSN:0028-4793
- Rights
- From New England Journal of Medicine, Manley BJ, Arnolda GRB, Wright IMR, Owen LS, Foster JP, Huang L, et al., 'Nasal high-flow therapy for newborn infants in special care nurseries', 380:2031-2040 DOI: 10.1056/NEJMoa1812077 Copyright © 2019 Massachusetts Medical Society. Reprinted with permission.
- Language
- eng
- Full Text
- Reviewed
- Hits: 7218
- Visitors: 7538
- Downloads: 328
Thumbnail | File | Description | Size | Format | |||
---|---|---|---|---|---|---|---|
View Details Download | ATTACHMENT02 | Publisher version (open access) | 199 KB | Adobe Acrobat PDF | View Details Download |