- Title
- CT perfusion improves diagnostic accuracy and confidence in acute ischaemic stroke
- Creator
- Campbell, Bruce C. V.; Weir, Louise; Desmond, Patricia M.; Tu, Hans T. H.; Hand, Peter J.; Yan, Bernard; Donnan, Geoffrey A.; Parsons, Mark W.; Davis, Stephen M.
- Relation
- NHMRC.567156
- Relation
- Journal of Neurology, Neurosurgery and Psychiatry Vol. 84, Issue 6, p. 613-618
- Publisher Link
- http://dx.doi.org/10.1136/jnnp-2012-303752
- Publisher
- BMJ Group
- Resource Type
- journal article
- Date
- 2013
- Description
- Background and objective: CT perfusion (CTP) is rapid and accessible for emergency ischaemic stroke diagnosis. The feasibility of introducing CTP and diagnostic accuracy versus non-contrast CT (NCCT) in a tertiary hospital were assessed. Methods: All patients presenting <9 h from stroke onset or with wake-up stroke were eligible for CTP (Siemens 16-slice scanner, 2×24 mm slabs) unless they had estimated glomerular filtration rate (eGFR)<50 ml/min or diabetes with unknown eGFR. NCCT was assessed by a radiologist and stroke neurologist for early ischaemic change and hyperdense arteries. CTP was assessed for prolonged time to peak and reduced cerebral blood flow. Technical adequacy was defined as 2 CTP slabs of sufficient quality to diagnose stroke. Results: Between January 2009 and September 2011, 1152 ischaemic stroke patients were admitted, 475 (41%) were <9 h/wake-up onset. Of these, 276 (58%) had CTP. Reasons for not performing CTP were diabetes with unknown eGFR (48 (10%)), known kidney disease (36 (8%)), established infarct on NCCT (27 (6%)), posterior circulation syndrome (25 (5%)) and patient motion/instability (16 (3%)). Clinician discretion excluded a further 47 (10%). CTP was more frequently diagnostic than NCCT (80% vs 50%, p<0.001). Non-diagnostic CTP was due to lacunar infarction (28 (10%)), infarct outside slab coverage (21 (8%)), technical failure (4 (1%)) and reperfusion (2 (0.7%)). Normal CTP in 86/87 patients with stroke mimics supported withholding tissue plasminogen activator. CTP technical adequacy improved from 56% to 86% (p<0.001) after the first 6 months. Median time for NCCT/CTP/arch-vertex CT angiogram (including processing and interpretation) was 12 min. No clinically significant contrast nephropathy occurred. Conclusions: CTP in suspected stroke is widely applicable, rapid and increases diagnostic confidence.
- Subject
- CT perfusion; acute ischaemic stroke; diagnostic accuracy
- Identifier
- http://hdl.handle.net/1959.13/1296899
- Identifier
- uon:19328
- Identifier
- ISSN:0022-3050
- Language
- eng
- Reviewed
- Hits: 5254
- Visitors: 5217
- Downloads: 0
Thumbnail | File | Description | Size | Format |
---|